Influence of Elevated Curing Temperatures on Ultrasonic Pulse Velocity in Portland Cement and Fly Ash Concretes

Mohammed Elsageer (1) , Ali Omar (1)
(1) Department of Civil and Architectural Engeneering, Sirte university, Sirte, Libya

Abstract

Ultrasonic Pulse Velocity (UPV) is a well-established non-destructive testing (NDT) technique that has been employed for over seven decades to evaluate the integrity and quality of concrete structures. It is extensively utilised to detect internal cracks, voids, and other discontinuities, as well as to monitor deterioration arising from exposure to aggressive chemical environments or repeated freeze–thaw cycles. Moreover, UPV is commonly applied as an indirect method for estimating the compressive strength of concrete. This paper investigates the influence of temperature on the development of UPV in Portland cement and fly ash concretes immediately after casting, with the objective of predicting early-age compressive strength. The technique was employed to assess the effect of varying curing temperatures on the early evolution of pulse velocity in these materials. In addition, the correlation between UPV and compressive strength was analysed, highlighting that the reliability of strength prediction is strongly dependent on the accuracy of UPV measurements. The paper demonstrates that ultrasonic pulse velocity (UPV) is a reliable and sensitive method for assessing early-age behaviour and predicting compressive strength in Portland cement and fly ash concretes (15–45% replacement). Curing temperature significantly accelerates UPV development, while fly ash delays early-age response without altering the overall trend. A strong exponential correlation confirms the robustness of UPV for strength estimation, highlighting its practical value for non-destructive evaluation and optimisation of curing conditions.

Full text article

Generated from XML file

References

[1] Bungey, J.H., S.G. Millard, and M. Grantham, Testing of Concrete in Structures T. Vol. 4 2006: Taylor & Francis. 286

[2] Malhotra, V.M. and N.J. Carino, The ultrasonic pulse velocity method in Handbook on nondestructive testing of concrete, T. Naik, V.M. Malhotra, and J. Popovics, Editors. 2003, CRC Press: West Conshohocken. pp. 14.

[3] L. d. Kirchhof, A. lorenzi, L. S Filho, Assessment of Concrete Residual Strength at High Temperatures using Ultrasonic Pulse Velocity .20 No.7 2015- The e-Journal of Non-destructive Testing - ISSN 1435-4934.

[4] Kaplan, M.F., The effects of age and water to cement ratio upon the relation between ultrasonic pulse velocity and compressive strength of concrete. Magazine of Concrete Research, 1959. 11 (32).

[5] Grantham, M., Diagnosis, inspection, testing and repair of reinforced concrete structures, in Advanced Concrete Technology Set, N. John and C. Ban Seng, Editors. 2003, Butterworth-Heinemann: Oxford. pp. 1-54.

[6] Tanigawa, Y., K. Baba, and H. Mori, Estimation of concrete strength by combined non-destructive testing method. ACI-American Concrete Institute, 1984. 82: pp. 57-76.

[7] Bungey, J.H., The validity of ultrasonic pulse velocity testing of in-place concrete for strength. NDT International 1980. 13 (6): pp. 296-300.

[8] Alcaino P, Maria HS, Cortes M, et al. Fast assessment of post-fire residual strength of reinforced concrete frame buildings based on non-destructive tests. MDPI Proc 2018; 2: 515.

[9] Li YH and Franssen J. Test results and model for the residual compressive strength of concrete after a fire. J Struct Fire Eng 2011; 2: 29-44.

[10] Tharmaratnam, K. and B.S. Tan, Attenuation of ultrasonic pulse in cement mortar. Cement and Concrete Research, 1990. 20 (3): pp. 335-345.

[11] Behera, B. Ultrasonic properties of fly ash composites, International Research Journal of Advanced Engineering and Science, Volume 2, Issue 1, pp. 190-193, 2017.

[12] Turgut, P., Research into the correlation between concrete strength and UPV values. NDT.net, 2004. 12 (12).

[13] Anderson, D.A. and R.K. Seals, Pulse velocity as a predictor of 28- and 90-day strength. ACI-American Concrete Institute, 1981. 78 (116).

[14] Sturrup, V.R., F.J. Vecchio, and H. Caratin, Pulse velocity as a measure of concrete compressive strength. In-Situ/Nondestructive Testing of Concrete, SP-82, V. M. Malhotra, ed., ACI-American Concrete Institute, 1984: pp. 201-227.

[15] Rao, S.K.; Sravana, P.; Rao, T.C. Experimental studies in ultrasonic pulse velocity of roller compacted concrete pavement containing fly ash and M-sand. Int. J. Pavement Res. Technol. 2016, 9, 289–301.

[16] Chen, T.T.; Wang, W.C.; Wang, H.Y. Mechanical properties ultrasonic velocity of lightweight aggregate concrete containing mineral powder materials. Constr. Build. Mater. 2020, 258, 119550.

[17] Pico, T. The TC-08 Thermocouple Data Logger offers industry–leading performance and is an inexpensive answer to your temperature measuring needs. 2005; Available from: http://www.picotech.com/thermocouple.html.

[18] Grosse, C.U., H.W. Reinhardt, M. Krüger, and R. Beutel, Ultrasound through-transmission techniques for quality control of concrete during setting and hardening. Workshop: Advanced testing of fresh cementitious materials, 2006.

[19] Guang, Y., K.v. Breugel, and A. Fraaij, Experimental study on ultrasonic pulse evalua-tion of microstructure of cementitious materials at early age. Material Search HERON 2002 2001. 46(3): pp. 161-168.

[20] Sayers, C.M. and A. Dahlin, Propagation of ultrasound through hydrating cement pastes at early times. Advanced Cement Based Materials, 1993. 1(1): pp. 12-21.

[21] Keating, J., D.J. Hannant, and A.P. Hibbert, Comparison of shear modulus and pulse velocity techniques to measure the build-up structure in fresh cement pastes used in oil well cementing. Cement and Concrete Research, 1989. 9: pp. 554-566.

Authors

Mohammed Elsageer
[email protected] (Primary Contact)
Ali Omar
Influence of Elevated Curing Temperatures on Ultrasonic Pulse Velocity in Portland Cement and Fly Ash Concretes. (2026). Journal of Pure & Applied Sciences , 25(1), 149-157. https://doi.org/10.51984/x1j8za28

Article Details

How to Cite

Influence of Elevated Curing Temperatures on Ultrasonic Pulse Velocity in Portland Cement and Fly Ash Concretes. (2026). Journal of Pure & Applied Sciences , 25(1), 149-157. https://doi.org/10.51984/x1j8za28

Similar Articles

You may also start an advanced similarity search for this article.

Effect of Marble Waste Powder as Cement Replacement on The Concrete Mixes

Mohammed Ali Abdalla Elsageer, Hmed Ahmeed Moftah , Abd-Alslam Mosbah Ziad and Mostafa Mohammed...
Abstract View : 778
Download :433

Activation functions of photodegraded carboxymethyl cellulose in solution: Viscosity measurements

Fathi Elashhab, Lobna Sheha, Rasha Sheltami, Tahani Alfazani, Abdelsallam Youssef
Abstract View : 719
Download :340

Relationship Between Compressive Strength and Tensile Strength in High-Strength Concrete

Ali Mahamoud Ghlaio, Imhemmed Hasan Algott, Abdalkrem khalifa Altresh, Abdullah Ali Shafter
Abstract View : 1334
Download :1185

Temperature and Humidity Effects on Fruit Fly Abundance and Distribution: A Comparative Study

Nawal Mahfoud, Haifa Ben Miloud, Gufran Enami, Abrar Abou Aqrab, Gufran Elghennai
Abstract View : 410
Download :103