Abstract

This paper is a part of condition monitoring of electrical submersible pumps (ESP). It is assigned for reviewing and discussing faults or malfunctions of this kind of pumps. Therefore, it reviews all-important information related to this machine, such as construction and operation. It focuses specifically on faults and details of these types of fault. Although there are slight differences between building submersible pumps in terms of the different technologies that different manufacturers use in making this type of pump, all kinds of these types of pumps are almost the same. In this context, pumps faults were reviewed based on major and common failures of this type of pumps.

Full text article

Generated from XML file

References

[1]- M S Kovalchuk, D.A.P., Diagnosis of Electric Submersible Centrifugal pump, in Earth Environmental Science 2018, saint petersburg mining university: saint Petersburg.

[2]- Lu Li, c.H.X.X., condition monitoring and fault diagnosis of electrical submersible pump based on wellhead electrical paerameters and production parameters. system science & control engineering, 2018. 6(3): p. 253 - 261.

[3]- Bantelay, D.T., investigating water supply system electro mechanical equipment problems: a case study of ethiopia. journal of optimization in industrial engineering, 2019. 12(2): p. 45-54.

[4]- abhay. Patil, A.d., Yi Chen, Daniel Steck, Chang-rui Bai, Yi ming Chen, Gerald Morrison, Mechanical Reliability of Electrical Submersible Pumps. chinese journal of turbomachinery, 2018. 60(5): p. 1.

[5]- G, T., Electrical submersible pumps manual. 2009: Gulf proffessional publishing.

[6]- Karassik, I.J., et al., Pump handbook. third edition ed. 2001: McGraw-Hill.

[7]- D, R., K, Michael Johanson, Pumping: Electrical Plant< Control and Instrumentation, 2009. p. 31.

[8]- UNHCR. Water Manual for Refugee Situations. 1992.

[9]- Thomas, S.B.a.V.V., Diagnoses of internal faults of threephase squirrel cage induction motor, in International Conference on Advances in Energy Conversion Technologies (ICAECT)2014, IEEE.

[10]- Liang, B., Condition monitoring of three-phase induction motors, 2000, The University of Manchester.

[11]- Bowen, B., The Differences Between Submersible & Immersible Motors, in pumps & system2014.

[12]- Hayri Arabaci, O.B. Analysis of Rotor Faults Effects on Submersible Induction Motor Efficiency. in World Congress on Engineering of Computer Science. 2013. San Francisco USA.

[13]- Bantelay, D.T., Investigating Water Supply System Electro-Mechanical Equipments Problems: A Case Study of Ethiopia. journal of optimization in industrial Engineering, 2019. 12(2): p. 45-54.

[14]- Panlong ZHANG a*, T.C.b., Guochao WANG c, Changzheng PENG d, Ocean Economy and Fault Diagnosis of Electric Submersible Pump applied in Floating platform. International Journal ofe-Navigation and Maritime Economy, 2017: p. 37-43.

[15]- Abhay.Patil, A.D., Yi Chen Daniel Steck, Chang-rui Bai,Yi-ming Chen, Gerald Morrison, Mechanical Reliability of Electrical Submersible Pumps. Chinese Journal of Turbomachinery, 2018. 60(5): p. 69-77.

[16]- Alvaro Jose Bazurto , E.C.Q., Rosaura Castrillon Mendoza, Causes and Failures Classification of Industrial Electric Motor, 2016, researchgate.

[17]- Neelam Mebala, R.D., motor current signature analysis and its applications in induction motor fault diagnosis. journal of system applications engineering &development, 2007. 2(1).

[18]- Pratesh Jayaswal, A.K.W., and K. B. Mulchandani, Machine Fault Signature Analysis. International Journal of Rotating Machinery, 2008.

[19]- S. Nandi, H.A.T., X li, condition monitoring and fault diagnosis of electrical motors, in IEEE trans. Energy Convers2005. p. 719-729.

[20]- R. Sathish, R.D., P. Ganga, Analyzing and Detection of Rotor Faults in Squirrel Cage Induction Motor Drives Using MATLAB. International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, 2015. 4(6).

[21]- Yannis L. Karnavas, I.D.C., Andreas Vrangas Fault Diagnosis of Squirrel-Cage Induction Motor Broken Bars based on a Model Identification Method with Subtractive Clustering in IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED), 2017, IEEE Tinos, Greece. p. 304-310.

[22]- M S Kova, A.P., Diagnosis of Electric Submersuble centrifugal Pump, in IOP2018, IOP: saint Petersburg Russia.

[23]- Marché, V. Electric Rotating Machine Eccentricities Faults Analysis with Flux. 2017.

[24]- Kamal.A.Sanad ¹, A.A.E.-S., Dina Mourad Study and Improvement of Submersible Motor Protection. International Journal of Engineering Inventions 2017. 6(10): p. 87-95.

Authors

Salem Al-Hashmi
Condition Monitoring of Electrical Submersible Pumps (Faults Review). (2021). Journal of Pure & Applied Sciences , 20(1), 71-74. https://doi.org/10.51984/jopas.v20i1.1070

Article Details

How to Cite

Condition Monitoring of Electrical Submersible Pumps (Faults Review). (2021). Journal of Pure & Applied Sciences , 20(1), 71-74. https://doi.org/10.51984/jopas.v20i1.1070

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

No Related Submission Found